1. AC Current:
<
200A
• Center wire in guides for best accuracy.
• Opposing currents cancel (use line-splitter when necessary).
2. AC / DC Voltage:
<
750V AC or 1000V DC
AC / DC Voltage (Low Z):
<
600V
• The tester will automatically choose AC voltage or DC voltage or
AC current based on the inputs detected.
• AUTO will be displayed when no input is detected.
• DO NOT Use low impedance (Low Z) mode at voltages greater
than 600 V.
• Use low impedance (Low Z) mode to reduce ghost voltages.
3. Resistance:
<
40MΩ
• Do not measure resistance on a live circuit.
4. Continuity
• Display shows resistance.
• Buzzer sounds if less than about 40Ω.
5. Non Contact Voltage (NCV):
>
25V AC
• NCV works independently of other tester functions. The function
knob can be in the off position.
• Press and hold.